cPS-P325/AC cPS-H325-HH |
cPS-P325/48 | cPS-H325/24 | cPS-H325/110 | cPS-H325/WDC | cPS-H640/AC | cPS-H640/48 | |
PICMG® Standards |
PICMG 2.11 CompactPCI | PICMG 2.11 CompactPCI 47-pin | |||||
Form Factor | 3U cPCI 2-slot |
3U cPCI 2-slot |
3U cPCI 2-slot |
3U cPCI 2-slot |
3U cPCI 2-slot |
6U cPCI 2-slot |
6U cPCI 2-slot |
Input Voltage |
90÷264 VAC | 36÷75 VDC | 18÷36 VDC | 66÷160 VDC | 16÷160 VDC | 100÷240 10% V AC | 36÷72 V DC |
Input Frequency |
47÷63 Hz | DC | DC | DC | DC | 50-60 5% Hz | DC |
Input Current |
3.6A @ 230 VAC | 6.3A @ 48 VDC | 14A @ 24 VDC | 2.8A @ 110 VDC | 1.3A @ 110VDC 3.3A @ 110VDC 0.45A @ 110VDC |
5.1A @115 V AC / 2.5A @ 230 V AC |
12A @ 48 V DC |
Inrush Current |
15A @ 240 VAC | 12A @ 75 VDC | – | 10.5A @ 110 VDC | 27A @ 110 VDC | < 30 A @230 V AC | N/A |
Output Current / Voltage |
25A @ 5V 20A @ 3.3V 4A @ 12V 1A @ -12V |
25A @ 5V 20A @ 3.3V 4A @ 12V 1A @ -12V |
25A @ 5V 18A @ 3.3V 5A @ 12V 0.5A @ -12V |
25A @ 5V 18A @ 3.3V 5A @ 12V 0.5A @ -12V |
20A @ 5V 20A @ 3.3V 11A @ 12V 1A @ -12V |
40A @ 5V 50A @ 3.3V 8A @ 12V 3A @ -12V |
40A @ 5V 50A @ 3.3V 8A @ 12V 3A @ -12V |
Minimum Load | 0.75A @ +12V | 0.75A @ +12V | 0.5A @ +5V | 0.5A @ +5V | – | 1.0A @ +5V | 1.0A @ +5V |
Rated Power | Typical 250W | Typical 250W | Typical 250W continuous | Typical 250W continuous | – | Typical 400 W continuous | Typical 400 W continuous |
Ripple | 60 mV @ +5 V and 3.3 V outputs 120 mV @ +12 V and -12 V outputs |
60 mV @ +5 V and 3.3 V outputs 120 mV @ +12 V and -12 V outputs |
50 mV @ +5 V and 3.3 V outputs 120 mV @ +12 V and -12 V outputs |
50 mV @ +5 V and 3.3 V outputs 120 mV @ +12 V and -12 V outputs |
50 mV @ +5 V and 3.3 V outputs 120 mV @ +12 V and -12 V outputs |
50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V outputs |
50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V outputs |
Hold-up Time | 20 ms | 4 ms | 5 ms after power fail signal | 5 ms after power fail signal | 30 ms | 10 ms after power fail signal | 10 ms after power fail signal |
Efficiency | Typical 82.6% | Typical 82.2% | Typical 78-79% | – | Typical 85-89% | Typical 79-83% | Typical 79-83% |
Output voltage sense |
Available at 5V, 3.3V, and +12V outputs | Available at 5V, 3.3V, and +12V outputs | Available at 5V, 3.3V, and +12V outputs and current sharing | Available at 5V, 3.3V, and +12V outputs and current sharing | Available at 5V, 3.3V, and +12V outputs and current sharing | Available at 5 V , 3.3 V and +12 V outputs | Available at 5 V , 3.3 V and +12 V outputs |
N+1 Redundancy |
Integrated ORing FETs / diodes for true redundancy | Integrated ORing FETs / diodes for true redundancy | Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation | Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation | Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation |
Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation |
Installed with internal OR-ing diodes at all outputs for N+1 redundancy operation |
Remote ON/OFF |
Available at [INH#] & [EN#] | Available at [INH#] & [EN#] | Available at [INH#] & [EN#] | Available at [INH#] & [EN#] | Available at [INH#] & [EN#] | Available at [INH#] & [EN#] | Available at [INH#] & [EN#] |
Power Failure Signal |
Available at [FAL#] pin | Available at [FAL#] pin | Available at [FAL#] pin | Available at [FAL#] pin | Available at [FAL#] pin | Available at [FAL#] pin | Available at [FAL#] pin |
Voltage Degrade Signal |
Available at [DEG#] pin | Available at [DEG#] pin | Available at [DEG#] pin | Available at [DEG#] pin | Available at [DEG#] pin | Available at [DEG#] pin | Available at [DEG#] pin |
Status LED | [INPUT OK] [FAULT] | [INPUT OK] [FAULT] | [POWER] means valid input voltage [FAULT] means a critical fault |
[POWER] means valid input voltage [FAULT] means a critical fault |
[POWER] valid input voltage [FAULT] critical fault | < Green LED > [POWER] means valid input voltage < Amber LED > [FAULT] means a critical fault |
< Green LED > [POWER] means valid input voltage < Amber LED > [FAULT] means a critical fault |
Earth Leakage | – | – | <0.5 mA @ 230 VAC <0.5 mA @ 48 VDC <0.5 mA @ 24 VDC | <0.5 mA @ 230 VAC <0.5 mA @ 48 VDC <0.5 mA @ 24 VDC | – | < 0.9mA @ 230 V AC > | N/A |
Operating Temperature |
-25°C to +50°C (-25°C to +105°C at case level) |
-25°C to +50°C (-25°C to +105°C at case level) |
0˚C to +70˚C (0˚C to +50˚C at full load with specified air flow. Derates linearly to 50% at +70˚C.) |
0˚C to +70˚C (0˚C to +50˚C at full load with specified air flow. Derates linearly to 50% at +70˚C.) |
-40°C to +85°C with free convention to supply up to 120W or with at least 400 LFM air flow to supply up to 300W |
0°C to +70°C (0 ̊C to +40 ̊C at full load with specified air flow. De-rates linearly to 50% at +70°C.) |
0°C to +70°C (0 ̊C to +40 ̊C at full load with specified air flow. De-rates linearly to 50% at +70°C.) |
Storage Temperature |
-40˚C to +85˚C | -40˚C to +85˚C | -40˚C to +85˚C | -40˚C to +85˚C | -40˚C to +90˚C | -20 ̊C to +85 ̊C | -20 ̊C to +85 ̊C |
Humidity | 5% to 95% non-condensing | 5% to 95% non-condensing | 5% to 95% non-condensing | 5% to 95% non-condensing | 5% to 95% non-condensing | 20% to 90% non-condensing | 20% to 90% non-condensing |
Shock | 20 G Acceleration amplitude, 11 ms duration, converter operating | 20 G Acceleration amplitude, 11 ms duration, converter operating | 15 G peak-to-peak, 11 ms duration, non-operation | 15 G peak-to-peak, 11 ms duration, non-operation | 15 G peak-to-peak, 11 ms duration, non-operation | 15 G peak-to-peak, 11 ms duration, non-operation | 15 G peak-to-peak, 11 ms duration, non-operation |
Vibration | Operation: 4.9 Grms, 20-500Hz, each axis | Operation: 2.2 Grms, 20-500 Hz, each axis | Operation: 1.88 Grms, 5-500 Hz, each axis | Operation: 1.88 Grms, 5-500 Hz, each axis | Operation: 1.88 Grms, 5-500 Hz, each axis | Operation: 1.88 Grms, 5-500 Hz, each axis | Operation: 1.88 Grms, 5-500 Hz, each axis |
Cooling Requirement | – | – | Min. 20 CFM is required for typical full power rating | Min. 20 CFM is required for typical full power rating | – | Minimum 20 CFM airflow is required for typical full rating power |
Minimum 20 CFM airflow is required for typical full rating power |
Certifications | IEC/EN 60950-1, UL/CSA 60950-1 | IEC/EN 60950-1, UL/CSA 60950-1 | IEC950, EN 55022, FCC Class A, IEC60950 Class I | IEC950, EN 55022, FCC Class A, IEC60950 Class I | EN 61000-4-3, EN 61000-4-5, EN 61000-4-6, EN 55022, FCC Class A, IEC 60950 Class I |
IEC950, EN 55022, FCC Class A, IEC60950 Class I | IEC950, EN 55022, FCC Class A, IEC60950 Class I |
MTBF | 279.000 h | 288.000 h | 240.500 h | 240.500 h | – | – | – |
Ordering Information | cPS-P325/AC | cPS-P325/48 | cPS-H325/24 | cPS-H325/110 | cPS-H325/WDC | cPS-H640/AC | cPS-H640/48 |
Alimentatori Modulari 47 PinGOMA ELETTRONICA2018-03-29T09:42:01+02:00