BPD-C300-120 | CPS-S300 | CPS-S300-HH | |
Not including face plate and connector | 6.40”L x 3.94”H x 1.47”W 162.5mm x 100mm x 37.34mm |
6.40”L x 3.94”H x 1.47”W 162.5mm x 100mm x 37.34mm |
|
Including face plate and connector | 6.67”L x 5.06”H x 1.59”W 169.4mm x 128.5mm x 40.3mm |
6.67”L x 5.06”H x 1.59”W 169.4mm x 128.5mm x 40.3mm |
|
Input/Output | FCI Connector 51939-667 | FCI Connector 51939-667 | |
Input Range |
16.8-137.5 VDC |
90-264 VAC | |
Frequency | – | 50-60 Hz | |
EMI filter | EN55022 Class B, FCC Part 15 | EN55022 Class B, FCC Part 15 | |
Inrush Current | <30A @ 14.4VDC | <32A @ 230 VAC | |
Input Current | 25A | 1.3A | |
Isolation | 2828 VDC (Input to Output) | 4242 VDC (Input to Output) | |
Efficiency | >89% | >90% @ 220 VAC | |
Active PFC | – | 0.99 | |
Switching Frequency | – | 134 KHz | |
Leakage | – | <300uA | |
DC Output | 12V plus 5VSB | 12V 25A max | |
Line Regulation | ±0.5% | ±2% | |
Load Regulation | ±1% on main output | ±2% | |
Ripple and Noise | 2% Pk to Pk | 1% Pk to Pk | |
Transient Response | 2% Maximum deviation; returns to initial condition in 1 msec max. | 2% Maximum deviation; returns to initial condition in 1 msec max. | |
Operative Temperature | -40°C to +70°C | -40°C to +70°C | |
Storage Temperature | -40°C to +85°C | -40°C to +85°C | |
Humidity | Up to 95% non-condensing | Up to 95% non-condensing | |
Shock | – | 15 G peak-to-peak, 11 ms duration | |
Vibration | – | 1.88 Grms, 5-500 Hz, each axis | |
MTBF | – | 89542 h @ 30°C according to MIL-HDBK-217 | |
Temperature coefficient | ±0.01% / °C | ||
Cooling | forced air cooling required | forced air cooling required | |
UL | no UL/IEC/EN60950-1 certificate | 60950-1:2005 (2nd Edition); Am 1:2009 | |
CUL | – | 60950-1:2005 (2nd Edition); Am 1:2009 | |
DEMKO | – | EN 60950-1:2006, EN 60950-1:2006/A11:2009, EN 60950-1:2006/A1:2010, EN 60950-1:2006/A12:2011 |